WAVE2 Firmware

Version Revision History
113-15801-076.zip [ 2020.09.02 ]

  • Made improvements on the serial interface and fixed bugs.
  • For the VPos and HPos setting commands, the specification of VPos and HPos was changed to by number of divisions.
  • For the trigger level setting command, the specification of trigger level was changed to by voltage.
  • Added commands for individually setting the oscilloscope parameters in the binary mode.
  • In Roll or Scan display mode (i.e. when timebase is set to 50ms/div or slower) the capture buffer is cleared (filled with 0V values) each time the timebase is changed. This is to ensure the captured data truly reflect the timebase and the measurements take correct values.
  • Under Y-X mode added access to adjust the frequencies and phases of the function signal generator outputs. This helps to view Lissajous-Figure using the Y-X mode and the built-in function generator.
  • Added a command (SendFV) for specifically reading frequency settings and voltage measurements. (Please see the updated document “WAVE2 Serial Interface” )
  • Some binary mode command format were changed. Please refer to the updated document “WAVE2 Serial Interface”
113-15801-070a.zip (Beta version) [ 2020.06.12 ]

  • Added serial interface to allow WAVE2 be controlled through a serial connection. For details please see “WAVE2 Serial Interface”.
  • Display the current incremental step size for a function generator parameter at the top of the step size input screen.
  • Fixed a couple of minor bugs.
113-15801-061.zip [ 2020.05.09 ]

  • Use button F3 as exit for the states of Menu, Measurement, WFMemory, Info, Freq input, Amp input, Ofs input, Duty input, Phase input, Step size input, Auto Off, and Power off.
  • Fixed a bug which caused false noise to appear on traces when time base was set to 20us or 10us.
  • Fixed a bug which caused reboot when SigGen mode was entered with time base setting greater than 20ms (i.e. 50ms or slower).
113-15801-060.zip [ 2019.12.10 ]
First official release.